Three Phase Energy Meter Test Bench |
Single Phase Energy Meter Test Bench |
Accuracy class: |
0.1/0.2/0.3 |
0.1/0.2/0.5 |
Voltage range:
|
| 3×57.7/100(V),3×220/380(V) |
| 3×230/400(V) ×240/450(V) |
| fine adjustment: 0-120% |
|
| 0-220V(230,240V option); |
| range: 0-120% fine adjustment: 0.01% |
|
Current range: |
3×0-100(A)
fine adjustment: 0-120% rated value |
0-100A; (option for 200A)
fine adjustment: 0.0001A (min) |
Frequency: |
45Hz-65Hz fine adjustment:0.1Hz |
45Hz-65Hz fine adjustment:0.1Hz |
Phase: |
0.0°-360.0° fine adjustment:0.1° |
0-360° fine adjustment:0.1° |
Stability of power output: |
voltage, current, pf ≤0.1% (3minutes)
|
<0.05% (180S) |
Deviation coefficient of power: |
≤1% |
voltage/ current < 0.5% |
Working power: |
220V,230,240
±
10% 50Hz or 60Hz |
220V,230,240
±
10% 50Hz or 60Hz |
Operation environment: |
20℃
±
5℃ humidity ≤75% |
20℃
±
5℃ humidity ≤75% |
Output capacity:(24 meters) |
voltage:750VA current: 1300VA |
current:800VA(120A),voltage:400VA |
Max. power consumption: |
3000VA (24 meters) |
1500VA (24 meters) |
load |
capacitance, resistance, inductance (≤4 μ F)
|
capacitance, resistance, inductance(≤4 μ F) |
Starting current output |
1mA (min) accuracy: 5%, starting power: accuracy 10% |
1mA (min), accuracy: 5%, starting power: accuracy 10% |
No. of calibrated energy meter: |
24 (6/12/24/32/40/48 on requested) |
24(6/12/24/32/40/48 on requested) |